专变负荷计算表

来源:华佗健康网
益阳美岸一期专变负荷计算变压器1BP回路编号主供备供1BL11BL21BL31BL41BL51BL61BL71BL81BL91BL101BL111BL12用电设备组名称、部位防火分区1-1、1-2消防动力用电防火分区2-1消防动力用电防火分区2-2消防动力用电防火分区2-3消防动力用电防火分区2-4、2-5消防动力用电防火分区2-1、2-2客梯用电消防水泵用电消防中心用电防火分区1-1、1-2、2-1、2-2公共照明防火分区2-3、3-1公共照明3#楼商铺用电2#楼商铺用电计算结果与变压器选择计算负荷Pe(kW)KxB与否平时火灾时59.5107.510.666.9140.910.663.9122.910.682.1191.910.676.9182.310.652.8010.601700303010.7114010.788.6010.7155010.7148010.7合计:937.7945.5总同有功无功期系负荷负荷目标数系数系数COSφ2KΣαavβav0.90.7设备容量变压器计算负荷COSφ0.80.750.750.750.750.60.80.80.850.850.850.85tgφ0.750.880.880.880.881.330.750.750.620.620.620.62UePjsQjsSjs(kV)(kW)(kVar)(kVA)0.383627450.384035540.383834510.384943660.384641620.383242530.380.382116260.388049940.386238730.38109671280.3810464122616457772换算系数111111111111出线回路计算、开关整定KxL111110.8110.70.70.70.7PjsL(kW)107.5140.9122.9191.9182.342.241703079.862.02108.5103.6IjsL壳架整定(A)电流电流2042252252854003152494003153894004003694004001072251253234003505710063143225160111225125194225225185225225变压设计选择器负变压器容量载率kVAβ8000.73计算选取计算有计算无补偿补偿补偿功功率功功率前的容量容量kWkVarCOSφ1kVarkVar0.760.95554120.78178240补后计算视补偿无功在功率后的kVarkVACOSφ1725810.96计算电流A838变压器2BP回路编号主供备供2BL12BL22BL32BL42BL52BL62BL72BL82BL92BL102BL8用电设备组名称、部位防火分区3-1、3-2消防动力用电防火分区3-3消防动力用电防火分区3-4消防动力用电防火分区2-3、2-4客梯用电防火分区3-3、3-4客梯用电生活水泵用电防火分区2-4、2-5、3-2公共照明防火分区3-3、3-4公共照明1#楼商铺用电路灯园林用电变配电房用电计算结果与变压器选择计算负荷Pe(kW)KxB与否平时火灾时8516710.675.4164.810.662.6176.710.666010.666010.690.8010.691.7010.7110.9010.7115010.750010.76610.7合计:819.4514.5总同有功无功期系负荷负荷目标数系数系数COSφ2KΣαavβav0.90.7设备容量变压器计算负荷COSφ0.80.750.750.60.60.80.850.850.850.80.8tgφ0.750.880.881.331.330.750.620.620.620.750.75UePjsQjsSjs(kV)(kW)(kVar)(kVA)0.385138640.384540600.383833500.384053660.384053660.385441680.386440760.387848910.388150950.383526440.38435529425685换算系数11111111111出线回路计算、开关整定KxL1110.750.750.80.70.70.70.81PjsL(kW)167164.8176.749.549.572.6464.1977.6380.5406IjsL壳架整定(A)电流电流317400350334400350358400400125225160125225160138225160115225125139225160144225160761001001110025变压设计选择器负变压器容量载率kVAβ6300.8计算选取计算有计算无补偿补偿补偿功功率功功率前的容量容量kWkVarCOSφ1kVarkVar0.760.94763820.75185210补后计算视补偿无功在功率后的kVarkVACOSφ1725060.94计算电流A731备用变压器3BP回路编号主供备供3BL13BL23BL33BL43BL53BL63BL73BL83BL93BL103BL113BL123BL133BL143BL153BL163BL173BL183BL19用电设备组名称、部位防火分区1-1、1-2消防动力用电防火分区2-1消防动力用电防火分区2-2消防动力用电防火分区2-3消防动力用电防火分区2-4、2-5消防动力用电防火分区3-1、3-2消防动力用电防火分区3-3消防动力用电防火分区3-4消防动力用电防火分区2-1、2-2客梯用电防火分区2-3、2-4客梯用电防火分区3-3、3-4客梯用电生活水泵用电消防水泵用电防火分区1-1、1-2、2-1、2-2公共照明防火分区2-3、3-1公共照明防火分区2-4、2-5、3-2公共照明防火分区3-3、3-4公共照明消防中心用电变配电房用电计算结果与变压器选择计算负荷Pe(kW)KxB与否平时火灾时000026.4010.326.4010.339.6191.910.326.4010.3000026.4010.326.4010.352.8010.366010.366010.390.8010.701700114010.788.6010.791.7010.7110.9010.73030116610.7合计:888.4397.9总同有功无功期系负荷负荷目标数系数系数COSφ2KΣαavβav0.90.7设备容量变压器计算负荷COSφ0.80.60.60.60.60.80.60.60.60.60.60.80.80.850.850.850.850.80.8tgφ0.751.331.331.331.330.751.331.331.331.331.330.750.750.620.620.620.620.750.75UePjsQjsSjs(kV)(kW)(kVar)(kVA)0.380000.38811130.38811130.381216200.38811130.380000.38811130.38811130.381621260.382026330.382026330.386448790.380.388049940.386238730.386440760.387848910.383023380.38435488392634换算系数1111111111111111111出线回路计算、开关整定KxLPjsL(kW)IjsL壳架整定(A)电流电流2252254003154003154004004004004003504003504004002251252251602251602251604003502251602251252251252251601006310025变压设计选择器负变压器容量载率kVAβ6300.73计算选取计算有计算无补偿补偿补偿功功率功功率前的容量容量kWkVarCOSφ1kVarkVar0.760.94393520.75170210补后计算视补偿无功在功率后的kVarkVACOSφ1424620.95计算电流A667注:①.紫色栏目如实填写;蓝色栏目查手册人工选择;黄色栏目自动计算生成; ②.KxB为变压器计算用需用系数; ③.KxL为出线回路计算用需用系数(干线系数);④.“设备容量”一栏,当属于“短时或周期工作制电动机”需要先换算Pe,电梯按院改进措施三十二换算,当一个回路混合功率因数或需用系数不同的负荷时,应分开计算或等效折算; ⑤.“计算负荷与否”一栏填“1”表示该回路计入变压器负荷,填“0”时表示不计入变压器负荷(如消防负荷),其回路编号填在“备供”一栏;⑥.“换算系数”用于同一回路带有不同类型用电负荷(功率因数不同、需要系数不同)时,等效换算用。⑦.“总同期系数”在0.9~1选取;⑧.“设计选择变压器容量”一栏按照大于等于“计算有功功率”选择;

因篇幅问题不能全部显示,请点此查看更多更全内容