地下防水工程施工方案
目 录
一、工程概况 ·············································································································· 1 二、编制依据 ·············································································································· 1 三、施工准备 ·············································································································· 2 四、地下防水工程主要施工方法 ······················································································ 3 五、SBS防水卷材施工注意事项及成品保护 ········································································ 8 六、质量要求 ·············································································································· 9 七、文明施工及安全保护措施 ························································································· 9
地下防水工程施工方案
一、工程概况 1、工程概况
郑州碧桂园一期(货量区)三标段137#楼,地下1层,地上18层高层建筑,筏板基础,剪力墙结构。地下室高度3.1m,抗震设防烈度7度,抗震等级二级。 2、地下防水工程概况
(1)防水等级及设防标准:防水等级为二级,设防标准采用抗渗混凝土自防水再附加防水层的做法,自防水混凝土抗渗等级:P6。
(2)附加防水层位置和材料:附加防水层设在迎水面(即外防水),当无法作迎水面设防时,才允许将附加防水层设在背水面(即内防水)。 防水材料和构造做法如下:
1)筏板基础底板防水(二级防水):100厚C15混凝土,20厚1:3水泥砂浆找平层;刷基层处理剂一遍;4厚SBS高聚物改性沥青防水卷材;点粘350号石油沥青油毡一层;50厚C20细石混凝土保护层;钢筋混凝土结构自防水底板(P6)。
2)侧墙防水(二级防水):2:8灰土分层夯实(宽不小于500);砌筑120厚灰砂砖墙保护层;4厚SBS高聚物改性沥青防水卷材;刷基层处理剂一遍;20厚1:2水泥砂浆找平;钢筋混凝土结构自防水。
以上适用范围:地下室其他部分(除地下车库顶板、配电间以外) 3)地下室配电间防水
底板防水(一级防水):100厚C15混凝土;20厚1:3水泥砂浆找平层;刷基层处理剂一遍;4+3厚SBS高聚物改性沥青防水卷材;点粘350号石油沥青油毡一层;50厚C20细石混凝土保护层;钢筋混凝土结构自防水底板(S6)。
侧墙防水(一级防水):2:8灰土分层夯实(宽不小于500);砌筑120厚灰砂砖墙保护层;4+3厚SBS高聚物改性沥青防水卷材;刷基层处理剂一遍;20厚1:2水泥砂浆找平;钢筋混凝土结构自防水。
(3)设防高度应比室外地坪高出500mm,附加防水层必须设保护层。所有穿地下室外墙的管道,必须预埋防水穿墙套管。桩头、变形缝、施工缝等特殊部位的防水做法详见节点详图。 二、编制依据
1
1、郑州碧桂园一期(货量区)三标段施工合同。 2、深圳市粤鹏建筑设计有限公司设计的基础施工图纸。
3、国家及行业现行建筑工程质量检验评定标准、施工及验收规范及规程和相关图集。
(1)《地下工程防水技术规范》(GB50108-2008) (2)《屋面工程技术规范》(GB50345-2012)
(3)《地下防水工程质量验收规范》(GB50208-2011) (4)《混凝土结构工程施工质量验收规范》(GB50204-2011) (5)河南省05系列工程建设标准设计图集(05YJ1) 三、施工准备 1、 作业条件
按照设计要求将混凝土垫层施工完毕,砖胎模处贴卷材面采用1:2水泥砂浆抹面压光,并经养护干燥,含水率不大于9%。基层应平整、牢固、不空鼓、不开裂、起砂,砖胎模阴阳角应做成不小于80mm圆角,卷材防水施工涂底油前应将表面清理干净。 2、技术准备
施工前应对图纸审核,了解本工程施工图中的防水细部构造和技术要求;在进场施工之前,现场的施工管理人员要对施工人员进行书面、口头和现场操作三种不同形式的交底。交底要细致、明确,由上而下逐级进行实施,直至所有施工人员完全明白为止。 3、材料准备
(1)本工程地下防水材料为SBS高聚物改性沥青防水卷材。卷材表面应平整,不允许有孔洞、裂纹、疙瘩等缺陷存在。每卷卷材接头不应超过一处,其中较短的一段不得2500mm。
(2)SBS卷材和基层处理剂必须经复试合格方能用于工程中。施工时还需要备用汽油作为施工时的辅助材料,备用汽油要妥善保管。
(3)采用热熔法铺贴,准备液化气罐和火焰喷枪、汽油喷灯、滚刷、油刷、刮板、铲刀、钢尺、壁纸刀、扫把、小线绳、喷灯、空桶等 4、人员准备
(1)防水分项工程是一项专业性很强的工种,必须选择资质过硬,并有多年防水施工经验的专业队伍施工。其负责人及班组长需持有相关单位颁发的防水施工人员上岗证书。
2
(2)为保证工期、质量、安全等项目顺利进行,项目部安排专职施工管理人员1名、专职安全员1名,防水人员10人。 四、地下防水工程主要施工方法 (一)筏板基础底板防水施工 1、工艺流程
施工准备→基层表面处理→ 底油一道→转角施工铺贴附加层→铺贴SBS卷材 ,滚压整平赶气→点粘350号石油沥青油毡一层→50厚C20细石混凝土保护层。 2、主要施工要点
(1)基层清理
基层清理时必须将突出基层表面的异物、砂浆疙瘩等铲除,并将尘土杂物清扫干净,最好用高压空气进行清理。阴阳角等处更应仔细清理,若有油污、铁锈等,应以砂纸、钢丝刷、溶剂等予以清除干净。
若基层高低不平或凹坑较大时,用掺加108 胶(占水泥重量的15 %)水泥浆刮平,视基层平整度情况刮1~2 遍即可,刮完后应养护。
基层要干燥,简易测定方法是:将 lm 见方的防水卷材倒盖在基层表面上,静置3~4h 后掀开检查,若覆盖处的基层表面与卷材上无水印,即可进行防水施工。
(2)涂刷基层处理剂(冷底子油)
在已经处理好的基层上涂刷基层处理剂,用长柄滚刷将基层处理剂涂刷在基层表面,要涂刷均匀,不得漏刷或露底。基层处理剂涂刷完毕,必须达到干燥程度(手摸不粘)方可施行热熔法施工,以避免失火。
(3)细部附加增强处理
对于阴阳角、管道根部等部位应做增强处理。方法是先按细部形状将卷材剪好,不要加热,在细部贴一下,视尺寸、形状合适后,再将卷材的底面(有热熔胶的一面),用手持汽油喷灯烘烤,待其底面呈熔融状态,即可立即粘贴在已涂刷一道密封材料的基层上,并压实铺牢; 加强层宽度不应小于500mm。
(4)弹粗线
在已处理好并干燥的基层表面,按照所选卷材的宽度留出搭接缝尺寸,将铺贴卷材的基准线位置线弹好,以便按此基准线进行卷材铺贴施工。
(5)热熔铺贴卷材
采用“滚铺法”,先铺粘大面、后粘接搭接缝。搭接宽度不小于100mm。
3
1)熔粘端部卷材。将整卷卷材(勿打开)置于铺贴起始端,对准基层上已弹好的粉线,滚展卷材约1m, 由一人站在卷材正面将这1m 卷材拉起,另一人站在卷材底面(有热熔胶)手持火焰喷枪,慢旋开关、点燃火焰。调成蓝色,使火焰对准卷材与基面交接处同时加热卷材底面与基层面,待卷材底面胶呈熔融状即进行粘铺,不得过分加热或烧穿卷材。再由一人以手持压辊对铺贴的卷材进行排气压实,不得有空鼓、皱折,这样铺到卷材端头剩下约30cm 时,将卷材端头翻放在隔热板上,再行熔烤,最后将端部卷材铺牢压实。
2)滚粘大面卷材。起始端卷材粘牢后,持火焰喷枪的人应站在滚铺前方,对着待铺的整卷卷材,点燃喷枪使火焰对准卷材与基层面的夹角, 喷枪距卷材及基层加热处约0.3~0.5m, 往复移动烘烤(不得将火焰停留在一处直火烧烤时间过长,否则易产生胎基外露或胎体与改性沥青基料瞬间分离),至卷材底面胶层呈黑色光泽并伴有微泡(不得出现大量大泡),即及时推滚卷材进行粘铺,后随一人施行排气压实工序。
3) 卷材搭接缝施工。卷材搭接缝以及卷材收头的铺粘是影响铺贴质量的关键之一。搭接缝不随大面一次粘铺,而做专门处理是为保证地下工程热熔型卷材防水层的铺贴质量。
搭接缝及收头的卷材必须 100%烘烤,粘铺时必须有熔融沥青胶从边端挤出,用刮刀随即将挤出的热熔胶刮封接浆;使接缝粘结严密。如下图所示:
卷材搭接示意图
为搭接缝粘结牢固,先将下层卷材(已铺好)表面的防粘隔离层熔掉,为防止烘烤到搭接缝以外的卷材,应使用烫板搭接粉线移动,火焰喷枪随烫板移动,由于烫板的挡火作用,则火焰喷枪只将搭接卷材的隔离层熔掉而不影响其他卷材。
粘贴搭接缝:一手用抹子或刮刀将搭接缝卷材掀起,另一手持火焰喷枪(或汽油喷灯)。从搭接缝外斜向里喷火烘烤卷材面,随烘烤熔融随粘贴,并须将熔融的沥青挤出,
4
以抹子(或刮刀)刮平。搭接缝或收头粘贴后,可用火焰及抹子沿搭接缝边缘再行均匀加热抹压封严,或以密封材料沿缝封严,不得有皱折、翘边、鼓泡等缺陷,铺贴后的卷材应平整、顺直,搭接尺寸正确,不得有扭曲现象。
4)铺贴双层SBS卷材时,上下层卷材不得相互垂直铺贴,且上下两层卷材的接缝应错开,长边错开1/3—1/2幅宽卷材。
5)SBS卷材铺贴完,将表面清理干净,经验收合格后,点粘350号石油沥青油毡一层。
6)卷材防水层铺设完,报监理工程师验收合格后方可进行下道工序防水保护层施工,保护层为50厚C20细石混凝土,要求振捣密实,表面平整,浇筑时切勿损伤防水卷材。
(二)侧墙防水施工
1、工艺流程:
结构穿墙螺杆孔封堵,结构面清理→20厚1:2水泥砂浆找平→拆除根部临时保护墙→ SBS 卷材施工→ 聚苯板施工(如果设计有)→ 保护墙施工
2. 主要施工要点:
(1) 结构穿墙螺杆孔封堵及结构面清理
将固定模板用的对拉螺杆及塑料锥形套取出。如果个别对拉螺杆变形,需将周边混凝土凿成直径50mm、深25mm 的外大内小的洞,在根部将对拉螺栓拆除或割除,再将所留空洞浇水洗净、湿润后,用防水砂浆塞实、抹平、压光。对模板接缝处的水泥浆用磨光机磨平,对外墙表面水泥浆等杂物用铲刀和钢丝刷清理干净,最后将混凝土表面灰尘扫净。
(2)在外墙上抹20厚1:2水泥砂浆找平。 (3)小心拆除根部临时保护墙,将防水层清理干净。
(4) 复杂部位增强处理:对于阴阳角、管道根部以及变形缝等部位应做增强处理。 (5) SBS 防水卷材施工:同底板。侧墙防水错缝及搭接见下图:
5
100横向搭接缝改性沥青防水卷材宽1m,每卷长10m纵向搭接缝≥1500100纵向搭接缝横向搭接缝≥1500100100横向搭接缝1000
侧墙防水做法示意图
(6) 聚苯板(如果设计有)及防水护墙施工。
外墙防水施工完即施工防水护墙,聚苯板随装随砌保护层,防水层应粘结牢固,结合紧密,厚度均匀一致。防水护墙厚120mm ,采用灰砂砖,防水护墙每隔5~8m 及阴阳角转角处留置施工缝。 (三)细部防水构造要求
1、地下室外墙水平施工缝留在高出底板300以上,并按下图1设止水带。
2、 地下室底板和外墙后浇带分别按图2、图3施工(其外防水做法按建筑图纸,本图仅作示意)。后浇带中底板钢筋和墙体水平筋全部断开。遇水膨胀止水条为缓膨型,7天的膨胀率不应大于最终膨胀率的60%,并应牢固可靠安装在预留槽内。
6
3、预应力管桩头防水细部构造
4、地下室侧墙预留方洞,地下室预埋穿侧墙套管防水构造
7
5、地下室外剪力墙螺栓防水
模板固定不宜采用螺栓拉杆或铁丝对穿。如必须用螺栓穿过防水混凝土结构时, 须采取有效止水措施。在螺栓对穿防水混凝土结构时,螺栓上应加止水环,防止混凝土内部造成引水通路。如图: 五、SBS防水卷材施工注意事项及成品保护 1、 热熔法同材性的关系。高聚物改性沥青防水卷材各品种的改性基料成分不同,因之软化点、熔融度及熔化速度亦不同。施工人员对所选卷材应进行探索试验,调节火焰距离以及烘烤时间,观察卷材底面热熔胶的熔融状态以及辅贴后卷材的粘贴强度,积累经验后,用于大面积施铺。
2、烘烤温度对卷材的影响。当喷嘴全部开放时,火焰的端部温度约为1300℃左右,火焰中心的温度约1100 ℃左右,调节喷枪开关可将温度降至1000~800℃左右。在这样的高温下实施热熔法施工,要求在对卷材材性了解的基础上熟练掌握持枪烘烤技术。
3、常温下,正确施工的热熔型卷材防水层,其粘结强度可大于0.5MPa,能满足质量要求。但在低温下施工,热熔胶冷却较快,往往影响粘铺质量,这就需要丰富的经验和熟练的操作技术,必要时,可同时使用两把火焰喷枪(或喷灯)进行加热操作,以使热熔胶熔融均匀,保证粘铺质量。
4、 采用热熔法施工,在点火时以及在烘烤施工中,火焰喷嘴严禁对着人。特别是立墙卷材热熔施工时,更应注意施工安全,应佩戴防护用品。
5、施工现场应清除易燃物及易燃材料,并备有灭火器等消防器材。消防道路要畅通。
6、 施工使用的易燃物及易燃材料应存放在指定处所,并有防护措施及专人看管。 7、六级以上大风,停止热熔施工。
8、汽油喷灯、火焰喷枪,以及易燃品等,下班后必须放入有人管理的指定仓库。 9、 室外温度达到-5℃时,若不采取保温措施时,应停止施工。
8
10、施工现场严禁穿硬底、高跟或钉子鞋上岗,以免破坏已施工完的防水层。 11、如发现卷材表面已经被破坏,要及时进行修补
12、施工完的防水层要及时采取保护措施,严禁在防水层上堆放物品或作为施工运输车道。 六、质量要求
1、卷材防水层应铺设在主体结构的迎水面。
2、SBS高聚物改性沥青防水卷材所选用的基层处理剂、密封材料等均应与铺贴的卷材相匹配。
3、材料进场后,应及时检验,合格后才能进行施工。
4、铺贴防水卷材前,基面应干净、干燥,并应涂刷基层处理剂;当基面潮湿时,应涂刷湿固化型胶粘剂或潮湿界面隔离剂。
5、基层阴阳角应做成圆弧或45。坡角,其尺寸应根据卷材品种确定;在转角处、变形缝、施工缝、穿墙管等部位应铺贴卷材加强层,加强层宽度不应小于500mm。
6、本工程防水卷材的搭接宽度为100mm,铺贴双层卷材时,上下两层和相邻两副卷材的接缝应错开1/3-1/2幅宽,且两层卷材不得相互垂直铺贴。卷材搭接宽度的允许偏差应为10mm。
7、热熔法铺贴卷材应符合下列规定:
(1)火焰加热器加热卷材应均匀,不得加热不足或烧穿卷材。
(2)卷材表面热熔后应立即滚铺,排除卷材下面的空气,并粘贴牢固, (3)铺贴卷材应平整、顺直,搭接尺寸准确,不得扭曲、皱折。
(4)卷材接缝部位应溢出热熔的改性沥青胶料,并粘贴牢固,封闭严密。
8、卷材防水层完工并经验收合格后应及时做保护层,底板细石混凝土保护层厚度不应小于50mm;侧墙宜采用软质保护材料或铺抹20厚1:2.5水泥砂浆;侧墙卷材防水层的保护层与防水层应结合紧密。
9、卷材防水层分项工程检验批的抽样检验数量,应按铺贴面积每100m2抽查一处,每处10m2,且不得少于3处。
10、采用外防外贴法铺贴卷材防水层时,立面卷材接槎的搭接宽度,高聚物改性沥青类卷材应为150mm,且上层卷材应盖过下层卷材。 七、文明施工及安全保护措施
1、文明施工:
9
(1)防水操作人员必须遵守经理的各项规章制度,必须服从上级指挥。 (2)施工人员必须注意卫生,严禁随地大小便,材料不准乱放。完工后现场清理干净,做到“工完场清”。施工时不要污染其工作面。
2、安全保护措施;
(1)有专职的安全员负责安全工作;
(2)材料放置应按指定地点有序存放,且应远离火源; (3)施工人员进入施工现场必须戴安全帽; (4)施工人员进入施工现场严禁烟火; (5)施工人员喝酒后严禁进入施工现场; (6)施工现场必须配备灭火器材
(7 施工人员进入施工现场严禁擅动工地任何电气设置及其它物品。