375 Field Communicator Menu Tree for FIELDVUER DVC6000
Instrument Level HC, AD, PD, and ODV
Hot Key1Instrument Mode2Control Mode3Protection4Stabilize/Optimize1-11-2-1-4Burst1Burst Enable2Burst Command3Cmd 3(Trending)Press1-2-2-1Basic Setup1Setup Wizard22Performance Tuner2Stabilize/Optimize41-2-1Mode and Protection1Instrument Mode2Control Mode3Restart Ctrl Mode4Burst Mode5ProtectionTuning1Travel Tuning2Integral Settings3Pressure TuningTvl/Press Control1Tvl/Press Select2Tvl/Press Cutoffs3Travel Limits4Pressure Control5End Pt Press ControlDynamic Response1SP Rate Open2SP Rate Close3Lag Time53Lead/Lag3Alerts1Electronics Alerts2Sensor Alerts3Environment Alerts4Travel Alerts5Travel History Alerts6SIS Alerts 36Alert Record6Status1Instrument Time2Calibration and Diagnostics3Operational4Integrator1-2-2-21-2Detailed Setup1Mode and Protection2Response Control3Alerts4Status5Instrument6Valve & Actuator7SIS/Partial Stroke31-2-2Response Control1Tuning2Tvl/Press Control3Input Char4Define Custom Char5Dynamic Response31-2-2-51-2-731Partial Stroke1PST Enable2PST Vars View/Edit1-2-6Configure / Setup1Basic Setup2Detailed Setup3Calibrate1-3Calibrate1Travel Calibration2Sensor Calibration3Relay Adjust4Restore Factory 4SettingsValve & Actuator1Manufacturer2Valve Serial Num3Valve Style4Actuator Style5Feedback Conn6Tvl Sensor Motion1-2-31-3-1Travel Calibration1AutoTvl Calib2Man Tvl CalibSensor Calibration1Press Sensors2Tvl Sensor Adjust3Analog In Calib1-2-4Online1Configure / Setup2Device Diagnostics3Device Variables2Device Diagnostics1Alert Conditions2Status3Device Record4Stroke Valve5Partial Stroke TestDevice Variables1Analog In2Tvl Set Pt3Travel4Drive Signal5Pressures6Variables7Device Information8DD Information1-3-231-2-52-33Device Record1Temp Max2Temp Min3Run Time4Num of Power UpsInstrument1-2-5-11General2Units3Analog Input Range4Relay Type5Zero Pwr Cond6Max Supply Press7Aux Term Mode8Inst Date and Time9Calib Status and LocGeneral1HART Tag2Message3Descriptor4Date5Valve Serial Num6Inst Serial Num7Polling Address1Field Communicator1Offline2Online3Utility4HART Diagnostics3-5Pressures1Pressure A2Pressure B3Pressure Diff4Supply Press23-6Notes:1-1-1 indicates fast-key sequence to reach menuThis menu is available by pressing the leftarrow key from the previous menu.2345613-7Not available in instrument level HC.Instrument level ODV only.Instrument level HC only.Instrument level HC, AD, and PD only.Fast key sequence for Alert Record with instrument level ODV is 1-2-3-7.
Device Information1HART Tag2Device ID3Manufacturer4Model5Device Rev6Firmware Rev7Hardware Rev8Inst Level9HART Univ RevVariables1Aux Input2Temperature3Temp Max4Temp Min5Cycle Count6Tvl Accum7Raw Tvl Input8Run Time9Num of Power Ups1-2-5-2Units1Pressure Units2Temp Units3Analog In UnitsAnalog Input Range1Input Range Hi2Input Range LoCalib Status and Loc1Last Calib Status2Calib Loc1-2-5-31-2-5-91
ii2345
6
DVC6000 Series
Tvl Tuning SetTravel Tuning1-2-2-1-111-2-2-1-1-112Tvl Tuning Set2Tvl Tuning Set3Tvl Prop Gain3Tvl Integ Enable4Tvl Velocity GainTvl MLFB Gain4Tvl Integ Gain5Stabilize/OptimizePeformance Tuner21-2-2-1-2Integral Settings11-2-2-1-3Pressure Tuning2Integ DeadZInteg LimitPress Tuning Set11-2-2-1-3-112Press Tuning Set2Press Tuning Set3Press Integ EnabPress Integ Gain3Press Prop GainPress MLFB Gain1-2-2-2-2Tvl/Press Cutoffs1Processor Impaired Alerts1-2-2-2-3Travel Limits11Tvl Limit Hi2Tvl/Press Cut HiTvl/Press Cut Lo1-2-3-1-32Offline/Failed Alrt Enab2Tvl Limit Lo3Power Starvation Alrt Enab1-2-2-2-4Pressure Control4Non-Critical NVM Alrt Enab11-2-3-1-2Drive Signal Alert15Critical NVM Shutdown6Flash ROM Shutdown1-2-2-2-5End Pt Press Control2Press Range HiPress Range Lo2Drive Signal Alrt EnabDrive Signal7No Free Time ShutdownReference Voltage Shutdown132End Pt Control Enab3PST Start Pt4Press Set PtPress Sat TimeElectronics Alerts1-2-3-3-1Aux Terminal Alrt11-2-3-112Aux Terminal Alrt Enab2Drive Current Shutdown3Aux InputAux Term Mode3Drive Signal AlertProcessor Impaired Alerts1-2-3-4-4Travel Deviation AlertSupply Press Lo Alrt1Sensor Alerts1-2-3-3-212Tvl Dev Alrt Enab1-2-3-212Supply Press Lo Alrt Enab3Tvl Dev Alrt PtTvl Dev Time2Tvl Sensor Shutdown23Supply PressSupply Press Lo Alrt PtTravel Limit Alerts3Temp Sensor ShutdownPress Sensor Shutdown1-2-3-4-512Tvl Alrt Hi Hi Enab1-2-3-3Environment AlertsTravel Alerts3Tvl Alrt Lo Lo Enab114Tvl Alrt Hi Hi PtTvl Alrt Lo Lo Pt2Aux Terminal AlrtSupply Press Lo Alrt22Travel3Tvl Set Pt1-2-3-4-6Travel Limit Hi/Lo Alerts1-2-3-44Tvl Alrt DB15Travel Deviation Alert2Tvl Alrt Hi Enab6Travel Limit Alerts3Tvl Alrt Lo Enab7Travel Limit Hi/Lo AlertsTrave Limit Cutoff Alerts4Tvl Alrt Hi PtTvl Alrt Lo Pt
1-2-3-5Travel History Alerts12Cycle CountTravel Cutoff Alerts3Cycle Count/Tvl Accum DeadbandTvl Accum1-2-3-4-71ODV1-2-3-5-1Cycle Count2Tvl Limit/Cutoff Hi Alrt Enab1-2-3-6SIS Alerts13Tvl Limit/Cutoff Lo Alrt Enab12Cycle Count Alrt Enab4Tvl/Press Cut Hi32PST Press Limit3Cycle CountCycle Count Alrt Pt5Tvl/Press Cut Lo3Press Dev Alrt Enab1-2-3-5-26Tvl Limit HiTvl Limit Lo
4Press Dev Alrt PtPress Dev Time1DeadbandHC, AD, PDAlert Record1Tvl Accum1-2-3-62Alrt Record Not Empty Enab1-2-3-5-31ODV3Alrt Record Full Enab2Tvl Accum Alrt Enab1-2-3-74Display Record3Tvl AccumTvl Accum Alrt Pt5Clear RecordAlert GroupsHC, AD, PD1-2-3-6-5Alert Groups1-2-4-1Instrument Time1ODV12Failure Group Enab2Inst Time Invalid EnabInst Date and Time1-2-3-7-53Valve Group EnabMisc Group Enab1-2-4-2Calibration and Diagnostics12Cal in Progress Enab3Autocal in Progress Enab4Diag in Progress EnabDiag Data Avail Enab1-2-4-3Operational12Press Ctrl Active EnabMulti-Drop EnabIntegrator1-2-4-412Integrator Sat Hi Enab3Integrator Sat Lo Enab4Integ LimitInteg DeadZMenu Tree for for 375 Field CommunicatorDevice Description Revision 171011
12
A
B
C
D
E
F
G
H
I
iiiDVC6000 Series
375 Field Communicator Menu Tree for
FIELDVUER DVC6000 AC Level
A
Hot Key1Instrument Mode2Protection1-1Basic Setup1Auto Setup2Manual Setup1-1-1Auto Setup1Setup Wizard2Relay Adjust3Auto Travel CalibManual Setup1Instrument Mode2Press & Actuator3Tuning & CalibPress & Actuator1Tvl/Press Select2Pressure Units3Max Supply Press4Actuator Style5Feedback Conn6Tvl Sensor Motion7Valve Style8Zero Pwr CondTuning & Calib1Tvl Tuning Set2Press Tuning Set3Relay Adjust4Auto Travel Calib1-1-2-3-1B1-1-21-1-2-2CTvl Tuning Set1Tvl Tuning Set2Tvl Prop Gain3Tvl Velocity Gain4Tvl MLFB GainPress Tuning Set1Press Tuning Set2Press Prop Gain3Press MLFB Gain1-1-2-31-2Detailed Setup1General2Measured Var3Response Control4Relay Type1-2-1General1HART Tag2Message3Descriptor4Date5Valve Serial Num6Inst Serial Num7Polling AddressMeasured Var1Analog In Units2Input Range Hi3Input Range Lo4Pressure UnitsResponse Control1Tvl/Press Select2Tvl Tuning3Integral Settings4Press Tuning5Pressure Control6Input Char1-1-2-3-2D1Setup 1Basic Setup2Detailed Setup3Calibrate1-2-21-2-3-2Tvl TuningTvl Tuning1-2-3-2-11Tvl Tuning Set1Tvl Tuning Set2Tvl Prop Gain2Tvl Integ Enab3Tvl Velocity Gain3Tvl Integ Gain4Tvl MLFB GainIntegral Settings1Integ DeadZ2Integ LimitPress Tuning1Press Tuning Set2Press Integ Enab3Press Integ GainPressure Control1Press Range Hi2Press Range LoPress Tuning Set1Press Tuning Set2Press Prop Gain1-2-3-4-13Press MLFB GainEOnline1Setup 2Display1-2-32Display1Device Information2DD Revision1-2-3-31-3Calibrate1Analog In Calib2Auto Travel Calib3Man Travel Calib4Restore Factory Settings5Calib Loc6Relay Adjust7Tvl Sensor AdjustDevice Information1HART Univ Rev2Device Rev3Firmware Rev4Hardware Rev5Inst Level6Device ID1-2-3-4F1-2-3-52-1G1Field Communicator1Offline2Online3UtilityHNotes:1-1-1 indicates fast-key sequence to reach menuThis menu is available by pressing the leftarrow key from the previous menu.1Menu Tree for 375 Field Communicator
Device Description Revision 1
I
5
6
1234
vii
因篇幅问题不能全部显示,请点此查看更多更全内容
Copyright © 2019- huatuo0.com 版权所有 湘ICP备2023021991号-1
违法及侵权请联系:TEL:199 1889 7713 E-MAIL:2724546146@qq.com
本站由北京市万商天勤律师事务所王兴未律师提供法律服务